Elder Project LP is a supplier of equipment to ensure the smooth operation of the mining industry. We have the ability to supply electric generator, power cables and related products

Electrical generators

Ideal for onsite and unexpected power outages such as load shedding. Smaller sizes appropriate for household use and larger silent ATS (automatic start) models for larger buildings or small businesses.
MG-5kW
Standby Silent Diesel Generator with ATS (380V)
Power output – 5kW (6.5kVa)
Rated voltage – Single Phase (220V, 50hz)
Current Output – 22.7A
Fuel consumption – 1.65 l/ph
Tank capacity – 15 litres
Dimensions – 675 x 485 x600mm
AVR/TFV- AVR fitted
Weight – 99kg
Oil capacity – 1.65 litres
Sound level – 80 db(A)
Running time – 4-6 hours
MG-16kW
Standby Silent Diesel Generator with ATS (380V)

Power output – 16KW (20kVa)

Rated voltage – Three Phase (380V)

Current Output – 30.3A

Fuel consumption – 4.4 l/ph

Sound level – 70 db(A)

Dimensions – 2000 x 1050 x 1100mm

AVR – AVR fitted

Weight – 800kg

Oil capacity – 7 litres

Tank capacity – 90 litres

Running time – 8-12 hours

MG-15kW
Standby Petrol Generator – Enclosed Type (230V)

Power output – 15KW (15kVa)

Rated voltage – Single Phase (230V)

Current Output – 68A

Average fuel consumption: 7.5l/ph

Tank capacity – 25 litres

Dimensions – 1320 x 730 x 880mm

AVR/TFV – Auto Voltage Regulator Fitted

Weight – 330kg

Oil capacity – 2.5 Litres

Running time – 3 – 4 hours

67.0 KVA PERKINS WATER COOLED SUPER SILENT DIESEL GENERATOR

Acoustically treated cabinet made from specific steel to protect against corrosion, stops unwarranted sound- the generator runs at a whisper quiet 63dB(A) at 7 metres distance. Brushless AVR controlled maintenance free alternators with rapid voltage control to prevent dangerous voltage swings. Three way valve for connection to a surplus fuel bowser (additional fuel pump maybe required) Bunded long range 350 litre fuel tank giving a massive 33 hours run time at 75% load.

Power Phase - Three Phase

Frequency - 50 Hz

Max Power Output (W) - 53.6 kW / 67 kVA

Tank Size - 350 Litres

Sound Level - 63 dB

Run Time - 33 Hours

Output Sockets -230V 32A, 400V 32A, 400V 63A

Dimensions - L2450 x W1000 x H1490

Power cables

Electric Power Cables for industrial installations
MG-15kW
Standby Petrol Generator – Enclosed Type (230V)
Type
Low voltage - 0,6 / 1kV
Maximum service temperature - 90ºC
Maximum short-circuit temperature - 250ºC (max. 5 s)
Minimum service temperature - -40ºC (fixed and protected installations)
Minimum bending radius - 10x cable diameter
Impact resistance - AG2 Medim severity

Installation conditions - open air, buried, in conduit, in tray

Cable conduits

General purpose flexible conduits (galvanised steel and stainless steel SS316) with high compression, tensile and impact strength. Nickel plated brass and stainless steel (SS316) fittings (metric and PG) with fixed and external threads. Flexible metallic cable protections conduits with PVC, PA6 and polyolefin (PO) covers and very high compression, tensile and impact strength. Nickel plated brass IP54 fittings (metric and PG) as well as IP65 compression fittings (metric and PG) with excellent pull-off strength. Both versions in various shapes and with fixed or swivel threads.
Galvanised Steel Conduit ø20mm
Material
Reel
General purpose flexible steel conduit offers high mechanical protection and is typically used in machines, plants, mines, data cabling and protection of hydraulic or pneumatic hoses.
  • High compression, tensile and impact strength
  • Very flexible
NCS Galvanised Steel Conduit with PA6 Coating black ø16mm
Reel
Flexible galvanised steel conduit with elastomeric PA6 coating is used in applications demanding resistance to high temperatures and to acids and solvents.
  • Good resistance to high temperatures
  • Good abrasion resistance
  • High compression, tensile and impact strength
  • Very flexible
  • Good resistance to alkalis and acids
  • Good resistance to chemicals
LTS Galvanised Steel Conduit with PVC Cover black ø25mm
Reel
General purpose flexible steel conduit offers high mechanical protection and is typically used in machines, plants, mines, data cabling and protection of hydraulic or pneumatic hoses.
  • Liquid-tight (IP68 and IP69k with LTS fittings)
  • High compression, tensile and impact strength
  • Good flexibility
  • Smooth outer cover does not wrinkle when bent
  • Good resistance to acids, petrol, oils and greases
  • Suitable for outdoor use

Power supplies

We offer the latest technology in a more compact package. Modern power supply units are a vital component in most areas of energy management and automation technology.
CP-D power supply
CP-D range of power supply units with its modular DIN rail component (MRDC) design fits all domestic installation and distribution panels.
Rated input voltage 24 V DC
Rated currents 3 A DC, 10 A DC, 20 A DC
Expandable with CP-B EXT.2 module
LEDs for status indication

High efficiency of more than 90%

CP-S power supply
Power supply are designed for a huge variety of applications, including machine building segments, this advanced range boosts an integrated 150 % power reserve for five seconds and operates at an efficiency of up to 94 %.
Rated supply voltage range from 100-240 V AC / 100-250 V DC
Rated output voltage 24 V DC
Rated output current of 3.0 A, 5.0 A, 10.0 A, 20.0 A and 40.0 A
High efficiency of up to 94 %
Power reserve design of 150 % for 5 s to start heavy loads
Output voltage adjustable via front-face rotary potentiometer “OUTPUT Adjust”, 24-28 V
Low power dissipation and low heating
Free convection cooling (no forced cooling)
Coated PCBAs
Open-circuit, overload and short-circuit protection
Integrated input fuse
DC OK - signaling output “13-14” (relay)
CP-C.1-A-RU redundancy unit offers true redundancy, available as accessory

Various approvals/marks, including cULus, DNV, EAC, RCM, SEMI F47, CE, UKCA

CP-B power supply
Ultra-capacitor based CP-B buffer modules serve to ensure a shortterm uninterrupted power supply system with a voltage of 24 V DC by buffering the load in case of power loss.

Power output – 15KW (15kVa)

Rated voltage – Single Phase (230V)

Current Output – 68A

Average fuel consumption: 7.5l/ph

Tank capacity – 25 litres

Dimensions – 1320 x 730 x 880mm

AVR/TFV – Auto Voltage Regulator Fitted

Weight – 330kg

Oil capacity – 2.5 Litres

Running time – 3 – 4 hours

Power transformers

The power transformer is used for regulating voltage and AC power transmission. It is applicable to power systems, industrial and mining enterprises, transportation, post and telecommunications sector, research institutes, etc.
PW-s20
A variety of transformers under 110kV are included in the product line: the stacked iron core structure series, the rolled iron core structure series, amorphous alloy series, etc. Smart and diverse structures and nice appearance make this product to meet the needs of different users.
Type - power
Configuration - immersed
Applications - industrial, telecommunications, for mining equipment
Electrical characteristics - three-phase
Other characteristics - AC, regulating, oil-immersed

Primary voltage - 10 kV, 20 kV

PW-s35
Type - power
Configuration - immersed
Applications - industrial, telecommunications
Electrical characteristics - three-phase
Other characteristics - AC, regulating, oil-immersed

Primary voltage - 35 kV

PW-s110
Type - power
Configuration - immersed
Applications - industrial, telecommunications, for mining equipment
Electrical characteristics - three-phase, voltage
Other characteristics - AC, regulating

Primary voltage - 110 kV

CAPACITORS

Capacitors are used in rail transit traction or ship drive converter, in various high-power industrial inverters, such as high-voltage variable frequency drive device and in power harmonic governance and SVG equipment.
Single and three phase Power Capacitor
High voltage capacitor is mainly used in the A. C. Power system with 50Hz to improve power factor.
Rated voltage - 6.3kV, 6.6kV, 6.6/√3kV, 7.96kV, 10.5kV, 11kV, 11kV, 11/√3kV.
Rated capacity - 33~334kvar
Capacity tolerance - -5 ~ 15%
Loss angel tangential value - film & papaer medium tg θ≦0.08%, film medium tg θ≦0.05%
Withstand voltage - it can afford AC2.15 or DC4.3 times rated voltage between the capacity pales, last about 10s without break or flash, BIL: 6kV(30kV), 10kV(42Kv)
Free discharge: it has the inner resistance,10min after cutting off the power supply, the residual voltage will reduce to 75V from √2 Un
Max. Current: running smoothly under the 1.3 time rated voltage, over voltage, capacity positive tolerance and harmonic wave which can not exceed 1 min each 24 hours
Max.Current: running smoothly under the 1.3 time rated voltage, over voltage, capacity positive tolerance and harmonic wave which can not 1.43 time rated current.
High Voltage AC Filter Power Capacitor
AC Filter Capacitors are mainly used in 50Hz and 60Hz AC power system, with other accessories (e.g. Reactors and resistors), can provide a low resistance path for one or multi harmonic current(s) and improve their power factors.
Environment temperature - -40 ~ +45℃
Height - ≦1000m
For bandpass filter, the deviation of actual and the rated capacitance are less than ±5%.
For high-pass filter, the deviation of actual and the rated capacitance are less than ± 7.5%.
The capacity of capacitors are recommended to be symmetrical deviation. The actual deviation is to be confirm after discussion between customers and our company.

Loss tangent (tgθ) ≦0.0005

Box type BSMJ three phases Power Capacitor
Self-healing type low voltage capacitor made of the advanced metalized film. The device is suitable for low voltage power network to improve power factor, reduce reactive loss and better the voltage quality.
Rated voltage - 230VAC, 400VAC, 525VAC, 690VAC, 750VAC, 1050VAC, 1200VAC
Rated frequency - 50Hz or 60Hz
Capacitance Tolerance - -5% - +10%
Tangent of the loss angle - with the power frequency rated voltage,
Withstand voltage - Between terminal 2.15 times rated voltage for 5 seconds, between terminals and container 2 Un+2Kv or 3KVAC choose the higher one for 10 seconds.
Max permissible over-voltage - 110% rated voltage
Max permissible over-current - 130% rated current

Self-discharge feature - Less than 50V in 3min after power broke down when the DC is√2Un as before increased by the capacitors

If you didn't find the product needed,

send us your request and we will contact you.

  • Suite 13013,
  • 43 Bedford Street,
  • London WC2E 9HA,
  • England